4 ton 410a piston size

Guidelines. Available in the following sizes. R-410A 25LB. CYLINDER 100 LB. CYLINDER 850LB. CYLINDER 1450 LB. Pressure-Temp Chart. R-410A. (R-32/125) (50 / 50 wt%) …

4 ton 410a piston size. Problem is I cant find any info on sizing of Rheem's pistons or the coil. Any help would be appreciated.” The Rheem air handler Model number told us that the 48 was for the BTU rating(4 ton as BaldLoonie pointed out) and the 82 stood for the piston size(as BaldLoonie pointed out as well).

Qty. $239.00. Diversitech 3/8" Sight Glass Sweat for Air Conditioner Condenser View Item. Add To Cart. Qty. $32.95. The Goodman GSXN3N2410 is a 2 ton cooling-only condenser unit. Providing a 13.4 SEER2 efficiency with a single stage, reciprocating compressor, the GSXN3N2410 is an inexpensive condenser to cool your home when paired with an AC coil.

The 3 to 15 ton Copeland Scroll Digital™ compressors described in this bulletin include the follow compressor model numbers: R-410A R-22 & R-407C ZPD34 to ZPD54K5 ZRD36 to ZRD81KC ZPD61-ZPD83, ZPD91, ZRD94 to ZRD125KC ZPD104, ZPD122KC ZPD103, ZPD120, ZPD137-182KC ZPD and ZRD digital scroll compressors are variableDimensions W H Suction Connection Liquid Connection ¾” Female NPT primary & secondary drain connections (Important: hand-tighten) 20⅛” 3” A 2.3” Specifications Model Dimensions Nominal Tons Connection Piston Size* Ship Weight W H A Liquid Suction (lbs) CAUF1824A6 13" 16¼" 13" 1½-2 ⅜" ¾" .059 18 CAUF1824B6 16½" 16⅛" 13" 1½-2 ...a. Exceptions for air conditioning (cooling only) applications, 1/4" liquid line may be used in: i. 1.5 ton applications for up to 100 equivalent feet (30.5 equivalent meters) with maximum 40’ (12.2 m) vertical lift ii. 2.0 ton applications for up to 75 equivalent feet (22.9 equivalent meters) with maximum 20’ (6.1 m) vertical lift b.3. Remove the piston from the mechanical fitting in liquid line. Remove and discard the O-ring. NOTE: Remove the piston. 4. Install new O-ring on fitting. O-ring is supplied in kit. 5. Using a back-up wrench, reattach the fittings. Tighten until bodies “bottom” or a definite resistance is felt. The valve will only fit in one direction of flow.Is your A/C System in need of repair or service? Get connected with the best heating and air conditioning contractors in your area. Call an AC Pro Certified contractor today for all HVAC services. Residential Fan Coil; with standard features:ENVIRONMENTALLY SOUND R-410A SYSTEMSFactory installed piston metering device with Teflon ringHigh efficiency ECM, 5-speed motorCopper tube/aluminum fin coil on standard modelsAvailable with industry exclusive t

Piston size chart r410a Air conditioning piston size chart Refrigerant-410a in a piston/cylinder arrangement is initially at 60 f, x = 1. it is then Charging chart for 410a. ... Mini split pressure chartPiston goodman conditioning 410a matched 4 ton rheem 14 seer three phase condenser, ra1448Piston metering device hvac installing. ...Oct 6, 2013 · I am installing a new cased coil Goodman CAPF36C6 WITH A NEW FURNACE GMVC95070 TWO STAGE 95% VS W. 4 TON blower. The old condenser is staying (Armstrong SCU1036). tHE OLD COIL HAS A #71 piston. The condenser calls for #68 but the specs say it's a 2 1/2 ton orifice. Considering the condenser is a 3 ton this has me a bit confused. Sx.e Vendor: ADVANCED DISTRIBUTOR PRODUCTS. Advanced Distributor Products #53, Florator Piston for 1.5 Ton R-22 and 2 Ton R-410A Air Handler Evaporator Coil. Specifications. Size: #53. Used On Item: 1.5 Ton R22, 2 Ton R410A Air Handler Evaporator Coil. Used On Model/Brand: 18, 24. QTY.The 1937-1938 Mack Jr half-ton pickup was the big-rig maker's downsize experiment. See pictures and learn about the 1937-1938 Mack Jr half-ton pickup. Advertisement Mack hoped [email protected]. (888) 601–0038. Follow Us. ADP 100000041 - Piston .73, 3 Ton R22, 3 1/2 Ton R410APiston Size 73. Can be used on 3 Ton R22 Coil or 3 1/2 Ton R410a Coil.Information from R410A 14 SEER AC/HP document. Condensing Unit. Air Handler / A-Coil. Piston Size / TXV Valve Model. SEER. "Preinstalled Piston". Attached Piston. If …100000042 ADP Piston - size 76 R410A (4 Ton) Abrpn: 100000042. Your No. This is non stock item. More Information. SKU. 104214. Default UOM.

Technical Information. Suction Line Size—Evaporator to Compressor. 50 °F through 30 °F (145 through 99 psig) 29 °F through 10 °F (97 through 64 psig) 9 °F through –10 °F (62 through 38 psig) Suggested Allowable Pressure Drop in psig = 2 °F 4.6 lb (2 °F) 3.5 lb (2 °F) 2.5 lb (2 °F) Equivalent Suction Line Length—Feet System ...1 3/8. 1 5/8. 1 5/8. 1 5/8. Refer to DuPont Refrigerant Expert, Version 2.0 for actual velocities and pressure drops. Equivalent length is actual length plus friction losses caused by fittings and accessories. Line sizes are expressed in outside diameter of type “L” copper tubing. Line sizes are calculated at rated full load system capacity. Goodman Piston Coil Chart. Johnstone Supply is a leading wholesale distributor for HVACR equipment, parts and supplies available and in-stock at local branches. According to Capital Home Builders, a 2,300-square-foot home needs a 4-ton air conditioner. Since there are 12,000 BTUs per ton, a house of this size needs a 48,000-BTU air conditi...3. Remove the piston from the mechanical fitting in liquid line. Remove and discard the O-ring. NOTE: Remove the piston. 4. Install new O-ring on fitting. O-ring is supplied in kit. 5. Using a back-up wrench, reattach the fittings. Tighten until bodies “bottom” or a definite resistance is felt. The valve will only fit in one direction of flow.

Husqvarna 455 rancher parts list.

410a piston size chart. R22/410 system410a piston chart Piston 1.5t r22 2t r410a (#53) adpGoodman piston chart. Chevy piston chart mahle 350 pistons block small rod powerpak inch bore stroke flat charts gif flattop application forged rodsPiston metering device orifice opening: 0.049 for r-410a 1.5 ton Mahle 5.7 4v sb chevy 350 powerpack …One ton of gravel covers 100 square feet at 2 inches thick, 80 square feet at 3 inches thick, 70 square feet at 4 inches thick or 60 square feet at 5 inches thick. These stones can...The duration of warranty coverage in Texas and Florida differs in some cases. At Goodman, we believe in American dependability. Units are designed, engineered and assembled in the U.S.A. Learn more about Goodman brand energy-efficient ARUE Series Air Handler - HVAC designed, engineered and assembled in the USA!Qty. $239.00. Diversitech 3/8" Sight Glass Sweat for Air Conditioner Condenser View Item. Add To Cart. Qty. $32.95. The Goodman GSXN3N2410 is a 2 ton cooling-only condenser unit. Providing a 13.4 SEER2 efficiency with a single stage, reciprocating compressor, the GSXN3N2410 is an inexpensive condenser to cool your home when paired with an AC coil.048 = 4 Tons ... Check piston size shipped with indoor unit to see if it matches required indoor piston size. ... Table 4 – AC with R-410A Refrigerant Long Line ...Advertisement ­ ­The dru­m brake may look complicated, and it can be pretty intimidating when you open one up. Let's break it down and explain what each piece does. Like the disc b...

Reviews, rates, fees and rewards details for the Bon-Ton Credit Card. Compare to other cards and apply online in seconds. We're sorry, but the Bon-Ton Credit Card may no longer be ...Piston size-non tXV use Tonnage R22 (F) R410A (G) Orifice Sz PART # Orifice Sz PART # 1T 0.041 3962 N/A N/A 1.5T 0.055 3999 0.049 4006 2T 0.059 4000 0.055 3999 2.5T …This system uses R-410A Refrigerant which operates at higher pressures than R-22. No other refrigerant may be used in this system. Gage sets, hoses, refrigerant ... 048 = 4 Ton 060 = 5 Ton 072 = 6 Ton Product Identifier E = Standard Efficiency Voltage 1 = 208/230-1-603 2 = 208/230-3-60 4 = 460-3-60 5 = 575-3-60 Additional OptionsThis manual is also suitable for: View and Download Daikin R-410A technical data manual online. Outdoor units. R-410A air conditioner pdf manual download. Also for: Rxs-g2v1b.3. Remove the piston from the mechanical fitting in liquid line. Remove and discard the O-ring. NOTE: Remove the piston. 4. Install new O-ring on fitting. O-ring is supplied in kit. 5. Using a back-up wrench, reattach the fittings. Tighten until bodies “bottom” or a definite resistance is felt. The valve will only fit in one direction of flow.14 SEER R410A AC Charge Chart 4 TON Cooling Outdoor Ambient Temperature(℉) Mode Liquid Pressure at Small Service Valve(psig) 14 SEER R410A AC Charge Chart 5 TON Cooling Outdoor Ambient Temperature(℉) Mode Liquid Pressure at Small Service Valve(psig) REFRIGERANT CHARGE FOR HP SYSTEM. 14 SEER R410A HP Charge …ADP Nominal 4 Ton, Upflow/Downflow 17.5" Wide L15 A-Coil, Aluminum, Non-Bleed TXV. Item. ... • Piston options include externally accessible body for easy piston change out and/or TXV installation. ... and E65 for size 42 models and higher. • Dual 3/4" FPT condensate drains on front-left and front-right side of drain pans.1 3/8. 1 5/8. 1 5/8. 1 5/8. Refer to DuPont Refrigerant Expert, Version 2.0 for actual velocities and pressure drops. Equivalent length is actual length plus friction losses caused by fittings and accessories. Line sizes are expressed in outside diameter of type “L” copper tubing. Line sizes are calculated at rated full load system capacity.: Get the latest Shandong Binzhou Bohai Piston stock price and detailed information including news, historical charts and realtime prices. Indices Commodities Currencies Stocks

[email protected]. (888) 601–0038. Follow Us. General Features:The M4AC40 is fully charged from the factory. This unit is designed to operate at outdoor ambient temperatures as high as 115 °F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is cert.

Piston size chart r410a Air conditioning piston size chart Refrigerant-410a in a piston/cylinder arrangement is initially at 60 f, x = 1. it is then Charging chart for 410a. ... Mini split pressure chartPiston goodman conditioning 410a matched 4 ton rheem 14 seer three phase condenser, ra1448Piston metering device hvac installing. ...Piston size chart r410a Air conditioning piston size chart Refrigerant-410a in a piston/cylinder arrangement is initially at 60 f, x = 1. it is then Charging chart for 410a. ... Mini split pressure chartPiston goodman conditioning 410a matched 4 ton rheem 14 seer three phase condenser, ra1448Piston metering device hvac installing. ...CAUF4860C6 20" 28" 25" 4-5 ⅜" ⅞" .093 48 CAUF4860D6 23" 28" 25" 4-5 ⅜" ⅞" .093 39 CAUF4961C6 20" 28" 25" 4-5 ⅜" ⅞" .093 54 CAUF4961D6 23" 27" 25" 4-5 ⅜" ⅞" .093 59 * Shipped with Coil Note: For a properly matched system and piston sizing information, refer to Goodman piston kit chart of the corresponding Goodman® outdoor unit. Residential Fan Coil; with standard features:ENVIRONMENTALLY SOUND R-410A SYSTEMSFactory installed piston metering device with Teflon ringHigh efficiency ECM, 5-speed motorCopper tube/aluminum fin coil on standard modelsAvailable with industry exclusive t The 3 to 15 ton Copeland Scroll Digital™ compressors described in this bulletin include the follow compressor model numbers: R-410A R-22 & R-407C ZPD34 to ZPD54K5 ZRD36 to ZRD81KC ZPD61-ZPD83, ZPD91, ZRD94 to ZRD125KC ZPD104, ZPD122KC ZPD103, ZPD120, ZPD137-182KC ZPD and ZRD digital scroll compressors are variable Sx.e Vendor: ADVANCED DISTRIBUTOR PRODUCTS. Advanced Distributor Products #53, Florator Piston for 1.5 Ton R-22 and 2 Ton R-410A Air Handler Evaporator Coil. Specifications. Size: #53. Used On Item: 1.5 Ton R22, 2 Ton R410A Air Handler Evaporator Coil. Used On Model/Brand: 18, 24. QTY. assembled, piped and wired at the factory to provide a single-piece. unit for shipment and rigging. Each unit is pressurized with a holding. charge of refrigerant R-410A for storage and/or shipping. The compact design, clean styling, small footprint, and quiet operation. make these condensing units and heat pumps suitable for almost any.a. Exceptions for air conditioning (cooling only) applications, 1/4" liquid line may be used in: i. 1.5 ton applications for up to 100 equivalent feet (30.5 equivalent meters) with maximum 40’ (12.2 m) vertical lift ii. 2.0 ton applications for up to 75 equivalent feet (22.9 equivalent meters) with maximum 20’ (6.1 m) vertical lift b.

Danny cevallos wife.

Sevier county sheriff's office inmate roster.

Available for environmentally sound R-410A systems; Factory installed piston metering device with Teflon ring on 1.5 - 4 ton sizes, TXV on 5 ton size; Sweat connections; Primary and secondary drain fittings; Multiple electrical entry locations; Time delay relay (TDR) Field installed heater packages from 5 kW - 30 kW available separately20-ton product line has been designed for use only with R-410A and POE oil (check unit model number for specific refrigerant). R-410A is a high-pressure refrigerant that …According to my chart the GSZ14048 takes a .80 piston. Also Goodman does not ship the piston with the 14 SEER condensers. I guess they wanted to save a buck per unit since most have the option for TXV too. You definitely can not count on the correct piston being shipped in the AH or coil either.Buy Goodman B1789857 2 Ton Orifice Kit for R-410A, 14 SEER Air Conditioner. Goodman technical support information, product brochures and more. Place Your Order by 1 pm for Same-Day Shipping*Heat Strip Size *Copper Refrigerant Line Set: Clear: 2.5 Ton Oxbox by Trane R410A Multi-Position Standard Efficiency Air Handler quantity. Add to cart. Compare SKU: J4AH4P30A1B00AA ... 4 Ton Goodman 15.2 SEER2 R410A Single Stage Heat Pump Split System. Rated 5.00 out of 5 $ 4,547.10 – $ 5,109.10-I work at a University, and am fighting a reoccurring issue with a residential split system not keeping up when temps get into the mid 80's and up. Unit is a 3 ton R410 I.C.P. unit, fixed orifice. Indoor unit calls for a 070 piston. This piston in it is 067. Condenser only references TXV, doesn't specify a piston size. Subcool is approx 10, …Apr 3, 2016 · Post Likes. Originally Posted by rsmith46. Use this easy formula to charge a piston R22 system by super-heat. WB times 3 minus OD temp minus 80 times 2. WB* x 3 -OD* - 80 x 2. I don't know of a formula for figuring the target SH on 410a, since only Goodman uses pistons. Thats my problem. It is the same. Residential Fan Coil; with standard features:ENVIRONMENTALLY SOUND R-410A SYSTEMSFactory installed piston metering device with Teflon ringHigh efficiency ECM, 5-speed motorCopper tube/aluminum fin coil on standard modelsAvailable with industry exclusive t ….

Size matters: Is the U.S. Navy really too small? September 9, 2015. By Zachary Cohen, CNN Updated 6:34 PM ET, Tue September 8, 2015 Sizing up the U.S. …The orifice will need to be changed. The question is whether the evaporator is rated for the 410 pressures. In the early days the R22 evaporators could not contain R410, but after 410 came out mfg’s started making heavier coils that could support 410 but R22 was cheaper and we had experience with it so we continued using it even though it …Maximum actual length is 200 ft (60.1 m) Maximum equivalent length is 250 ft (76.2 m) A hard shut--off TXV is required on the indoor unit beyond 50 ft (15.2 m), other accessories per lengths and heights in Table 4 below. A hard …1048A16C 4 TON R22 CASED COIL 17.5" W/R410A PISTON. Sku#: 116614. Details. Air Conditioner Evaporator Coil; Item Coil; Size 17-1/2 Inch x 21-1/4 Inch x 20 Inch; Material Copper Alloy (Tubing); Used On Item Air Conditioner; Pressure Rating 2490 PSI; Refrigerant Type R-22; Coil Size 4 Ton. SPECIFICATIONS.Get the lowest price on a 3.5 to 4 Ton Trane RunTru Evaporator Coil - 4MXCB006AC6HCA - Fast Delivery, ... Liquid Line Size: 3/8 inch : ... R-410a : Suction Line Size: 7/8 inch : Warranty: 5 Year Parts, 10 Year Evaporator Coil: California Residents: see Prop 65 WARNING: Accessories . Thermostats WE RECOMMEND.CE - Carrier Enterprise4 - R-410A only. P. Cased - Painted. 6 - R-22 or R ... ¹ (ft²). ² Shipped with Coil. Note: For a properly matched system and piston sizing information, refer to ...Residential R-410A Split System Air Conditioners. ICP has evaluated the use of ¼” and c” liquid lines for R-410A refrigerant air conditioner. cooling-only systems. R-410A refrigerant lends itself well to the use of smaller liquid lines in. either retrofit applications with existing linesets, or new systems when cost saving is a. 4 ton 410a piston size, R-410A environmentally friendly refrigerant. System Size (Tons): 4 ... you need to throw out your old air conditioner that hasn’t kept you cool in ages and switch it out with the ProDirect 4 Ton 15 SEER Split System A/C Condenser from MRCOOL. ... the piston flow control device manages the speed and volume of the refrigerant as it runs to ..., This system uses R-410A Refrigerant which operates at higher pressures than R-22. No other refrigerant may be used in this system. 5742637-YIM-D-0620 4 Johnson Controls Ducted Systems Nomenclature. Z E 036 CA2 A 1 A A 1 A 1., May 13, 2014 · I just had a new condenser and evaporator installed, a Goodman model GSX130481BC 4 ton condenser and 4-5 ton Goodman model CHPF4860D6DB coil using R410A. The day after install, the system produced about a 14 degree F drop between the air intake and outlet vents. , May 4, 2017 · A 0.067 orifice is about right for a 3 ton 13SEER R-410A system, or at least really close, depending on which manufacturers chart you look at. Generally you should ignore the orifice size listed on the indoor coil, and go with what the outdoor unit calls for, which in this case is a TXV. , Advertisement ­ ­The dru­m brake may look complicated, and it can be pretty intimidating when you open one up. Let's break it down and explain what each piece does. Like the disc b..., Apr 25, 2017 ... ... 410a charging chart can help you fix your ... The orifice size in the piston determines how much liquid refrigerant enters the evaporator coil., Apr 25, 2017 ... ... 410a charging chart can help you fix your ... The orifice size in the piston determines how much liquid refrigerant enters the evaporator coil., Liquid Line Size: 3/8 in Metering Device: Piston Motor Rating: 1/3 hp Motor Type: PSC Nominal Capacity: 3.5 ton Power Source: 208/230/1 Refrigerant Type: R-410A Series: B6BMM0 Suction Line Size: 7/8 in Supply Air Opening: 12-7/8 x 18-1/4 in. Similar Products Found in: > ELECTRIC FULL-SIZE SYSTEM, 4 ton 410a what size piston do I need to put in the air handler coil? The new condenser did not come with a piston 4 ton air handler 4 ton condenser. PHM-----Faced with the choice between changing one's mind and proving that there is no need to do so, almost everybody gets busy on the proof., Residential R-410A Split System Air Conditioners. ICP has evaluated the use of ¼” and c” liquid lines for R-410A refrigerant air conditioner. cooling-only systems. R-410A refrigerant lends itself well to the use of smaller liquid lines in. either retrofit applications with existing linesets, or new systems when cost saving is a., R-22 R-410A Florator Piston for 60 (Piston Size 93) All Air Handler Model. Cat # : 17N36. Model/Part # : 10000047. Sign in for pricing and availability. Print. Quantity: Add to Cart. Save to List., Qty. $239.00. Diversitech 3/8" Sight Glass Sweat for Air Conditioner Condenser View Item. Add To Cart. Qty. $32.95. The Goodman GSXN3N2410 is a 2 ton cooling-only condenser unit. Providing a 13.4 SEER2 efficiency with a single stage, reciprocating compressor, the GSXN3N2410 is an inexpensive condenser to cool your home when paired with an AC coil., Maximum actual length is 200 ft (60.1 m) Maximum equivalent length is 250 ft (76.2 m) A hard shut--off TXV is required on the indoor unit beyond 50 ft (15.2 m), other accessories per lengths and heights in Table 4 below. A hard …, Piston Size Optional TXV SEER "Preinstalled Piston" Attached Piston If Preinstalled Piston Replace Required AC M4AC3018B1000AA M4CXC024BA1CAAA C050 MAYTXVACAC1818AA 13 056 050 YES M4CXC025BB1CAAA C050 MAYTXVACAC1818AA 13 056 050, 060, 061 YES M4CXC030BB1CAAA C050 MAYTXVACAC1818AA 13 063 068, 058, 057, 064, 050, 070, 051 YES, piston sizing is only a concern for heat pump heating operation. Follow piston change recommendations in this Guideline for proper heat pump heating operation (see Table …, Mortex coils for manufactured housing are universal R22/R410a. The metering device (piston or TXV) is the key. It is common to replace a R22 condenser with a R410a condenser, keep the evap coil and change piston or TXV to match. The SEER on these suck when new. Disclaimer, I will only change out a manufactured house system if coil …, Condensing Unit Air Handler / A-Coil Piston Size / TXV Valve Model SEER "Preinstalled Piston" Attached Piston If Preinstalled Piston Replace Required AC M4AC4018C1000AA M4CXC028BA1CAAA 051 / (MAYTXVACHP1830AA) 14 064 068, 058, 057, 050, 069, 051 YES M4CXC030BB1CAAA 051 / (MAYTXVACHP1830AA) 14 063 068, 058, 057, 064, 050,, Thermostatic Expansion Valves can be mounted in any position on the evaporator coil inlet and are reliable, efficient and virtually trouble-free. Select the TXV to correspond with the tonnage of your air conditioner or heat pump, as well as to match the type of refrigerant your systems uses, R-22 (standard) or R-410A (new alternative)., [email protected]. (888) 601–0038. Follow Us. General Features:The M4AC40 is fully charged from the factory. This unit is designed to operate at outdoor ambient temperatures as high as 115 °F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is cert. , Even longtime industry executives are amazed at the growth. At 171,598 tons, the newest vessel from fast-growing MSC Cruises is of a size that would have been unthinkable just a co..., Goodman GPH1348H41 - Goodman 4 Ton 13 SEER Packaged Dedicated Horizontal Heat Pump, R-410A Refrigerant- The Goodman® GPH13H 13 SEER Package Heat Pump provides energy-efficient cooling and heating performance in one self-contained unit. The Goodman GPH13H is housed in a heavy-gauge, galvanized-steel cabinet that …, Apr 3, 2016 · Post Likes. Originally Posted by rsmith46. Use this easy formula to charge a piston R22 system by super-heat. WB times 3 minus OD temp minus 80 times 2. WB* x 3 -OD* - 80 x 2. I don't know of a formula for figuring the target SH on 410a, since only Goodman uses pistons. Thats my problem. It is the same. , outdoor goodman indoor piston outdoor goodman indoor piston section indoor piston kit section indoor piston kit coil btu's size part no. coil btu's size part no. ckl18-1 18000 .052 (2) clj36-1 36000 .071 (2) 24000 .059 to .052 b17898-52 (3) 42000 .078 to .073 b17898-73 (1) 29000 .059 to .052 b17898-52 (3) 47000 .082 to .073 b17898-73 (1) , According to Capital Home Builders, a 2,300-square-foot home needs a 4-ton air conditioner. Since there are 12,000 BTUs per ton, a house of this size needs a 48,000-BTU air conditi..., Compressor oil is needed in the air conditioning systems as lubricant and heat removal. Sealing of rotors and piston is another function of the oil. Expert Advice On Improving Your..., Contact Us. [email protected]. (888) 601–0038. Follow Us. Learn more. ADP 100000036 - Piston .53, 1 1/2 Ton R22, 2 Ton R410APiston Size 53. Can be used on 1 1/2 Ton R22 Coil or 2 Ton R410a Coil., The Goodman piston size chart for R22 is designed to help you select the correct piston size for your system if you’re still using this refrigerant, but it’s important to weigh the …, Piston size-non tXV use Tonnage R22 (F) R410A (G) Orifice Sz PART # Orifice Sz PART # 1T 0.041 3962 N/A N/A 1.5T 0.055 3999 0.049 4006 2T 0.059 4000 0.055 3999, 4 To 5 Ton TXV Kit - R-410A Refrigerant. ( 5 Reviews) Model: Blueridge BGH4TXV03. $ 109.99. Or as low as. Buy in monthly payments with Affirm on orders over $50. Learn more. You save: 30%. Compare to: $157.92. , 3/8 80 (24.4) 35 (10.7) vertical or 80 (24.4) total 80 (24.4) For Heat Pump systems, the chart below shows when an application is considered Long Line. HP WITH R−410A REFRIGERANT LONG LINE DESCRIPTION ft (m) Beyond these lengths, long line accessories are required Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor , The 410 pistons are smaller than 22. I assumed it was because the pressure on 410 is higher. You have to make sure you change them especially if your dealing with a 2 1/2 or 3 1/2 ton system. The coil is equipped with the right piston for freon. For example a 3 1/2 ton takes a 73 piston but a 4 ton coil comes with a 84., Product Overview. C35 Indoor Coil C35-48B-2F. Up-flow, full-cased models. 1.5- to 5-ton capacities. Large surface area for high-efficiency operation. Lighter, rifled aluminum tubing, hairpins, distributor and header tubes for improved durability in certain environments. Non-corrosive, UV-resistant polymer drain pan with dual connections., Nominal Capacity 2.5 ton. Flow Rate 1000 cfm. Power Source 208/230/1. Refrigerant Type R-410A. Liquid Line Size 3/8 in. Suction Line Size 3/4 in. Filter Size 16-3/8 x 21-1/2 in. Motor Type ECM. Motor Rating 1/3 hp. Dimensions 49-5/8 in H x 17-5/8 in W x 22-1/16 in D. Metering Device Piston