Generac load shed module led off

1. Any unit built/manufactured prior to January 1, 2005. 2. Costs of normal maintenance (i.e. tune-ups, associated part(s), adjustments, loose/leaking clamps, installation and start-up). 3. Any failure caused by contaminated fuels, oils, coolants/antifreeze or lack of proper fuels, oils or coolants/antifreeze. 4.

Generac load shed module led off. RTS Series Transfer Switch. With the RTS transfer switch, you can choose to cover every circuit all the time or only essential circuits when paired with a generator sized to your application. RTS open transition transfer switches are ideal for residential, commercial and light industrial applications. 100 - 400 Spec Sheet.

The led is off which says that there is no power going to the module. Don't go by the LED. Take a multimeter and test across the red and black terminals. You should have 240V arriving from your breaker box. If not then there is a break in the wiring but more likely your module is bad. Try swapping the module and see if the problem goes with it.

So I have no other load-shed modules yet, One of the attached photos is of the interior of the transfer switch, where you can see the A/C load shed module. When the load shed module for the A/C is finally hooked up, I will be trenching 24" deep over to the outdoor heat pump unit, burying PVC conduit, and running a 20 gauge thermostat wire ...Turn off utility power supply to transfer switch when utility supply voltage is compatible with transfer switch and load circuit ratings. Press MANUAL on control panel to crank and start engine. Allow engine to warm up for approximately five minutes. Set generator MLCB (generator discon-nect) to ON (CLOSED).The Generac load shed module in their ATS sheds when generator drops to 58hz I believe, then there are 4 load sheds positions available. 1 and 2 has set of dry contacts to break any 24 volt circuit, ( a/c, auxilary heat relays etc.) AND a voltage output set of contacts also. Voltage output on 1-4 is decided by jumpers (field provided) to send ...Watch this video to find out about the Generac Synergy home standby generator, which is the first residential standby generator with variable speed technology. Expert Advice On Imp...We would like to show you a description here but the site won’t allow us. Features. Generac 100-Amp Smart Management Module (SMM) Designed to optimize the performance of a standby generator. Direct Replacement/Same Footprint. Easily swap out the older SMM with the new, hassle free. Self-Aware & Operate Autonomously. In-line installation means that No control wire required.

4 posts · Joined 2019. #1 · Oct 24, 2019. I have an install with 2 Generac Smart Management Modules to lockout 2 EV chargers. They are setup to lockout the load when on generator. The manual has an insert that updates the behavior to lockout when the generator gets overloaded. They don't seem to lockout in either of these cases.The old Carrier air handler had a 60 amp from the main panel feeding the strips then the yellow and black on the molex plug had 240v coming from the 20 amp in the Generac transfer switch. The new Goodman has everything run through the heat strips. What do I need and how do I set it up so the heat strips are unable to work automatically …Get free shipping on qualified Load Shedding Module, Generac Generator Accessories products or Buy Online Pick Up in Store today in the Outdoors Department.programmable interface module (PIM), and load shed kit. The RDC2 controller's 2-line LCD screen displays status messages and system settings that are clear and easy to read, even in direct sunlight or low light. RDC2 Controller Features D Membrane keypad: d OFF, AUTO, and RUN pushbuttons d Select and arrow buttons for access to systemGenerac Fuel Valves/Shut-off; Generac Fuses; Generac Gaskets; Generac Hoses; Generac Ignition Coils; ... Generac Load Shed Modules; Generator Manuals . Briggs & Stratton Technical/Owners Manuals; ... Generac Alb Frame Sprt 4 Led Mod Horiz 10000046102 Product Videos. Custom Field ...Generac Assembly Pcb 2.4 Ignition Module 0G46490SRV. $1,124.76. Add to Cart. Generac Assembly Pcb Ignition Module 2.4L No-Turbo 0H1083. OEM Generac Ignition Parts & Accessories. Get free shipping on qualified Load Shedding Module, Generac Generator Accessories products or Buy Online Pick Up in Store today in the Outdoors Department. If you have questions, please contact your AMRtechnologiesInc. representative at 1-800-213-0227 or submit your question [email protected]. Generac-Smart Management Modules SMM 7000. Smart power where you need it. Whole-house coverage may not fit every budget. With a power management system, your generator can work smarter.

An optional redundant load sequencing controller is available for sites which desire fully automatic backup operation; this redundant controller is Generac’s PowerManager® Permissive and Load Shed Controller (PM-PLS). The PM-PLS is capable of monitoring online generators and provides automatic permissive and load shed functions similar to the1 Section 2: General Information and Setup. 2 Load Management Options. 3 Smart Management Module (Smm) 4 Jumper Locations. 5 Section 3: Installation, Tests, and …Buy Generac Load Shed ASSY W/VSCF 0K0220ASRV Part# 0K7341A: ... Lock-Feature and LED Status Display for Convenient Operation, Gray ... As this is the latest version of the Load Shed Module that includes flexibility to use the newer 24-volt switches as well as the older 120-volt ones, If you use the older 120v modules (DLMs) you will need to ...The old Carrier air handler had a 60 amp from the main panel feeding the strips then the yellow and black on the molex plug had 240v coming from the 20 amp in the Generac transfer switch. The new Goodman has everything run through the heat strips. What do I need and how do I set it up so the heat strips are unable to work automatically …

Dncss st louis bb con st louis mo.

Sale. $129.15. $140.99. Quantity. Add to Cart. Generac 10000004183 Transfer Switch Controller (SACM) Load Shed Module. Replacement load shed module for shedding A/C's and other loads during generator overload. Also known as the SACM. This new style transfer switch controller also has an integrated transfer relay and fuses.Bypass it for good and add a soft start on your AC unit. The SMM from generac are good for nothing but burning up. The SMM interrupts the 24 volt to the compressor contactor coil. Bypass the SMM and get your AC back up online. I installed (yes they are easy) the SoftStart modules in the AC compressor.I have used below format to Turn ON/OFF LEDs. 1. @Light On# 2. @Light Off# Circuit Design: (using LEDs) ARDUINO Source Code: Given below the code to Turn ON/OFF LEDs. Copy and Paste it in ARDUINO Code explorer and burn the code in ARDUINO by selecting required COM Port. Then Send Message from Sender Mobile as mentioned above.Installation and wiring with the NEW Generac® SMART A/C Module Installation/wiring with the 240 Volt Coil NO Contactor 65 & 100 Amp Compatibility Guarantee All of our load shedding devices are fully field tested and GUARANTEED to be 100% compatible with any make or model generator or transfer switch.Honeywell modules. These modules work GREAT. An SMM is designed to optimize the performance of a standby generator. The system can consist of up to eight individual Smart Management Modules. Unlike other load management systems that depend on another control device, the SSM modules are actually self aware and operate autonomously.

Features. Generac 100-Amp Smart Management Module (SMM) Designed to optimize the performance of a standby generator. Direct Replacement/Same Footprint. Easily swap out the older SMM with the new, hassle free. Self-Aware & Operate Autonomously. In-line installation means that No control wire required.Hmmm, the only time iv seen the load shed module fry like that were the original versions that didnt have the standoffs on the back. I see yours had the standoffs. Does your switch have the stick on plastic insulator pad behind the load shed module. Its attached to the switch box itself. A kind of insulator. The coils can fry under 2 conditions.POWERFUL & EASY TO USE. 172,200 total lumens. Coverage: 19,526 ft2 (1,840 m2) at 0.5 ft-c. Set up in one minute. Ergonomic, 2-handled manual winch standard; electric winch option. Simple, easy-to-use controls. Rear hood with gas-assisted pistons provides ease of access for maintenance. 750 hour service interval.Ziller Tech Aug 12, 2016. The new 'wireless' load shed modules are called SMM's. We use them all the time and they are great! They have their own on board PCB which does all of the controlling. It monitors incoming frequency and when it notices generator power, it takes over. The module just installs between any 240v (only 240v) load and the ...LED (D)—Provides module status. See Table 2-3. Contactor (E)—Normally OPEN. If generator begins to overload, the contactor opens to take load off generator power. See Connections. Mounting Holes (F)—Internal enclosure mounting holes provide clean and sturdy mounting. Directional Arrows (G)—Provided for mounting pur-poses.Product Description. Generac Digital Load Management (DLM) Module 0059370. This Digital Load Module (DLM) is used to control or turn on and off load under the control of the load shed module (LSM) in the transfer switch. The DLM consists of a 2 pole N.O relay mounted in an enclosure. The 2-pole relay is rated to control: Current -50A resistive ... Module operates with standard load shed logic. See Table 2-1 for more information. LOCKOUT DISABLED A or B Utility Power is available on module output. NOTE: Duration of Return to Utility timer is longer in Mode B. Table 2-3. LED States State LED State Mode Note Shed 1 second flash (1 On – 1 Off) Generator Module detected an overload and shed ... RTS Series Transfer Switch. With the RTS transfer switch, you can choose to cover every circuit all the time or only essential circuits when paired with a generator sized to your application. RTS open transition transfer switches are ideal for residential, commercial and light industrial applications. 100 - 400 Spec Sheet.Cutting Edge - Innovative - Next Generation are all terms that have been used to described PSP Products’ Generator Load Shedding Systems.Our line of “Industry Firsts” includes Magnetic Latching Relays instead of contactors to eliminate hum and chatter, extend unit life and control loads up to 200A. Universal 4 - 12 channel controllers and wireless load drop …

RTS Series Transfer Switch. With the RTS transfer switch, you can choose to cover every circuit all the time or only essential circuits when paired with a generator sized to your application. RTS open transition transfer switches are ideal for residential, commercial and light industrial applications. 100 - 400 Spec Sheet.

Ive been installing Generac load shed devices for 13+ years and have never come across this issue...under normal utility power, and with no loads being applied, expect for the little light indicators, the load shed devices are randomly shutting off the attached circuits. After sometime, again randomly the circuits are being re-engaged.The load shed modules are Generac 7000 50 Amp Smart Management Module. We have two ductless mini-split air conditioners connected to them, timed to come on at 5 and 6 min. after the generator starts. We have an electric oven that is set (via switch in the SMM) to not come on when the generator is on. https://amzn.to/3fy07AD4 posts · Joined 2019. #1 · Oct 24, 2019. I have an install with 2 Generac Smart Management Modules to lockout 2 EV chargers. They are setup to lockout the load when on generator. The manual has an insert that updates the behavior to lockout when the generator gets overloaded. They don't seem to lockout in either of these cases.The Generac load-shedding is frequency based, and there is a hard limit of 8 load shedding devices; that includes the relay contacts built into the transfer switch. So if you used two of the internal HVAC relays, you could only use 6 additional load shedding modules. The load shed modules each have an 8-position dial to set priority.Generator Sizing Calculator. Generac Smart Management Modules SMM | 6873. Smart Management Modules (SMM) are wire-free. Up to 8 SMM can be installed with a compatible automatic transfer switch. You can set the load priority for each - putting you in control of which circuits matter most. With a power management system your generator can work ...Waukesha, WI 53189 No reproduction allowed in any form without prior written 1-888-GENERAC (1-888-436-3722) consent from Generac Power Systems, Inc. www.generac.com... View and Download Generac Power Systems RXSW200A3F owner's manual online. Automatic Transfer Switch 200 Amp, Single Phase, 240 VAC, …That leaves the conventional approach of removing power from the heat pumps and electric backup heat. This is done by Generac System Management Modules (SMMs) that are connected to each load to be shed and disconnect the power to the load when needed. The HVAC dealer consulted with their Carrier distributor rep who has said at times that ...

Doberman pinscher puppies for sale in texas.

Bradley dr lee cancer.

Delivering to Lebanon 66952 Choose location for most accurate options All. Select the department you want to search in Priority Dial (A)Sets module priority Lockout Switch (B) Prevents load from operating when syst em is operating under generator power. Test Button (C) Disables contactor output for a specified time. LED (D) Provides module status with easy viewing through the external viewing window located in the upper right corner of the module. W1 W2 H1 H2 D1Sale. $32.36. $34.99. Quantity. Add to Cart. Generac 0J0603/0J5807 2 Pole 40A 120V Coil Load Shed Module Contactor. 0J603 was replaced by 0J5807. These were used in the DLM and PMM type load shedding devices among others. This is for the replacement contactor only, not the entire module. Generac replacement parts will also usually fit the ...Hello, I have the previous model Generac 200 amps ATS. My last hook up is the load shedding for my A/C unit. I run the Y wire coming from the furnace to load 1. Then run Y wire from load 1 back to A/C. My question is there are two open spots on the load module. Orange in color. The top first one says load supply 1.Generac Fuel Valves/Shut-off; Generac Fuses; Generac Gaskets; Generac Hoses; Generac Ignition Coils; ... Generac Load Shed Modules; Generator Manuals . Briggs & Stratton Technical/Owners Manuals; ... Generac Assembly Pcb Tri Led Display 0G7714. MSRP: $12.49 $10.49. Add to Cart Compare. Quick view. Generac Power Systems ...First, ensure the generator is off and disconnected from its power source. Locate the circuit breaker and check if it’s in the ‘off’ or ‘tripped’ position. If it is, switch it back to ‘on’. Start the generator, and if the green light comes on, a tripped circuit breaker is the issue.Smart Management Modules. Generac's Smart Management Modules allow for more coverage with a smaller generator through smart load management. Get more coverage with less when you use Generac's power management option. WIRE-FREE TECHNOLOGY Increased affordability with wireless modules, lowering installation cost and providing the best whole ...LED (D) - Provides module status. See Table 2-3. Contactor (E) - Normally CLOSED. If the generator begins to overload, the contactor opens to take the load off generator power. The contactor also opens to take the load off generator power. See Connections. Mounting Holes (F) - Internal enclosure mounting holes provide clean and sturdy ...In between the transfer switch and the panels I have a Generac 50-Amp Smart Management Module. I noticed today that my SSM keeps reseting. The timing is random but it happened many times today. I cycled power to the unit but still same issue. ….

1 Section 2: General Information and Setup. 2 Load Management Options. 3 Smart Management Module (Smm) 4 Jumper Locations. 5 Section 3: Installation, Tests, and Troubleshooting. 6 Electrical Specifications. 7 Connections. 8 …New - OEM Generac Replacement Transfer switch controller (SACM). This load shed module will arrive in Generac packaging. Model # 10000004183. If you find that your transfer switch is not changing positions during a power outage, a failed load shed module could be to blame. Generac replacement parts will also usually fit the following Generac ...Generator Help - Troubleshooting/Repair/Installation. Transfer Switches. Load shed module blew up. Automatic/Manual transfer switch repair, wiring & …item 5 Generac 7000 50 Amp 120V/240V Smart Management Module, Load PrioritizationGenerac 7000 50 Amp 120V/240V Smart Management Module, Load Prioritization. $115.00. +$8.95 shipping.The heat strips fight against the A/C so the air is warm and not cold. If the outside coils are not frosted up it only lasts for 15 seconds or so. If it's cold and moist outside the defrost could last for a few minutes. Like. This is an older thread, you may not receive a response, and could be reviving an old thread.• The conductor tightening torque is 375 in-lbs. (Line), 275 inlbs. (Load - ATS) 1.3.3 Load shed modULe (Lsm) The Load Shed module is designed to prevent an overload on the generator when it is supplying the customer loads (see Figure . 1.2). Up to six loads can be managed by the LSM; 2 air conditioner loads and 4 other loads.Battery Modules: 3.0 kWh PWRcell DCB Battery Module PWRcell ATS PWRcell 100A ATS : PWRcell 100A Service Rated ATS PWRcell 200A Service Rated ATS: Load Management: PWRmanager 12 Relay Load Manager 50A Smart Management Module (SMM) 100A Smart Management Module (SMM) PWRcell Accessories: PWRcell LTE Accessory Kit : 8-16A SureStart Soft-StarterBuy Generac Load Shed ASSY W/VSCF 0K0220ASRV Part# 0K7341A: ... Lock-Feature and LED Status Display for Convenient Operation, Gray ... As this is the latest version of the Load Shed Module that includes flexibility to use the newer 24-volt switches as well as the older 120-volt ones, If you use the older 120v modules (DLMs) you will need to ...Oem Generac 10000004183 Load Shed Module (sacm) - New in Box. Free shipping. GENUINE GENERAC 10000004183 ASSY SMART MODULE, SAME DAY SHIPPING. $136.99. Generac load shed module led off, Generac RTSW400A3 Details and Features. 400 Amp Single phase; 120/240v Configuration; Service Rated; Integrated Load Shed Module for smart load management; Aluminum Enclosure; Generac RTSW400A3 Specifications. Click to view Generac specs. Qty : $ 2,999.00 Add to Cart. Description ..., Kohler Harness, Load Shed GM81370. $417.66. Add to Cart. Generac Harness Power Zone Permissive Load Shed 10000011389., See more Generac Load Shed ASSY 0k0220asrv Part No 0K73... Share | Add to Watchlist. Picture 1 of 3. ... Sell now. Generac Older Model 100/200Amp Automatic Transfer Switch Wired Load Shed Module. A Wiring Man (1763) 98.9% positive; Seller's other items Seller's other items; Contact seller; US $115.00. No Interest if paid in full in 6 mo on $99 ..., Generac 16kW Guardian whole home generator with load shed, full cycle, Load shedding, defined as "the act or process of disconnecting the electric current on certain lines when the demand becomes greater than the supply", is a very important element of implementing emergency backup generator and peak shaving programs. Backup generator power transfer (cutover) and peak shaving both create a number of negative ..., Generac Smart Management Modules allow for more coverage with a smaller generator through smart load management. 100 Amp, 240 Volt single-phase SMM (Smart Management Module) manages inrush of electrical loads on startup and automatically sheds them during generator overload conditions. It contains built-in intelligence., I would rather invest in a proper sized generator at continuous load. Than buy that. But that's just my view. pay now or pay down the road with nuisance failures of the module or starting components, with possible compressor life limitations. I have seen the newest hard start packaging in the past and they always fail to perform., The Generac Smart Management Module 7006 manages 240-Volt 100-Amp Loads. Load Priority Setting determines which loads start and run first. Up to 8 Smart Management Modules per Generac Standby System control different loads with priorities set from 1-8. A 240-Volt circuit from the circuit breaker panel supplies each Smart Management Module., Now, let's dive into the technical details and standout features of the 22 kW Generac generator. Here are some key specifications that make this generator a top choice: Feature. Specification. Rated Wattage (Propane) 22,000 Watts. Rated Wattage (Natural Gas) 19,500 Watts. True Power Technology., Sale. $32.36. $34.99. Quantity. Add to Cart. Generac 0J0603/0J5807 2 Pole 40A 120V Coil Load Shed Module Contactor. 0J603 was replaced by 0J5807. These were used in the DLM and PMM type load shedding devices among others. This is for the replacement contactor only, not the entire module. Generac replacement parts will also usually fit the ..., programmable interface module (PIM), and load shed kit. The RDC2 controller's 2-line LCD screen displays status messages and system settings that are clear and easy to read, even in direct sunlight or low light. RDC2 Controller Features D Membrane keypad: d OFF, AUTO, and RUN pushbuttons d Select and arrow buttons for access to system, Enter your model or serial number to find Generac specifications, manuals, parts lists, FAQs, how-to videos, and more for your product. About ... SMM MODULE NC Y20 File Type Manual (PDF) Item Number Language; Owner Manual: OMNL INTEL LOAD MGMT NC GEN SPFR: 10000030487: es/fr: Owner Manual: OMNL INTEL LOAD MGMT NC GEN EN: 10000030493: EN: Spec ..., I plan to use the priority one 120 volt output to control a 100 amp contactor with a 120 volt coil. A DLM module is only good for switching 50 amps. The actual normal load on this circuit is normally just a few amps and occasionally bumps up to maybe 30 amps when drying clothes, but I can't use a relay that is rated less that the circuit feeder., The 50 Amp Smart EMS TM Control Module utilizes Intellitec's RV Multiplex/PMC (Programmable Multiplex Control) System as the communications link between the Display Pane l and the Distribution Panel. As an additional diagnostic feature, the system includes two Communication Status LED's on the Control Module., Sale. $129.15. $140.99. Quantity. Add to Cart. Generac 10000004183 Transfer Switch Controller (SACM) Load Shed Module. Replacement load shed module for shedding A/C's and other loads during generator overload. Also known as the SACM. This new style transfer switch controller also has an integrated transfer relay and fuses., Generac Generator Tech Talk Generac Air Cooled Generators; ... Current (and 2008) National Electrical Code requires that unless you use automated load-shedding equipment added into the package. ... In my case a Load Shed module will allow me to run the loads that I want with a smaller genset and save me quite a bit of money. The $80.00 for the ..., Generac Fuel Valves/Shut-off; Generac Fuses; Generac Gaskets; Generac Hoses; Generac Ignition Coils; ... Generac Load Shed Modules; Generator Manuals . Briggs & Stratton Technical/Owners Manuals; ... Generac Assembly Pcb Tri Led Display 0G7714. MSRP: $12.49 $10.49. Add to Cart Compare. Quick view. Generac Power Systems ..., Installation and wiring with the NEW Generac® SMART A/C Module Installation/wiring with the 240 Volt Coil NO Contactor 65 & 100 Amp Compatibility Guarantee All of our load shedding devices are fully field tested and GUARANTEED to be 100% compatible with any make or model generator or transfer switch., We would like to show you a description here but the site won't allow us., Management generator power Whole house generators Generac shed load. Generac smm 240v 50amp. Shed load panelGenerac 80kw 22kw manualzz Generac shedding module load loads question dlmGenerac 0k7341a load shed replaced 0k0220asrv same day shipping. Generac 6873 smart management module …, The test button simulates an overload condition and will disable the SMM for a specified time, whether on generator or utility power. An LED provides the module’s status. Product resources. A copy of the 50 and 100-Amp SMM user manuals can be downloaded from their product pages on Generac.com., Installation and Configuration. Reference the PWRcell ATS Installation and Owner's Manual (Part No. A0001501191)and the PWRcell Inverter Installation and Owner's Manual for complete instructions on Generator Integration with PWRcell. Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2023 Generac Power ..., Notes: The Model 3 charges at a rate of 37 miles/hour at 50 amps, and 44 miles/hour at 60 amps. I acknowledge the difference is negligible to me and many, so putting in a 50 amp circuit would lower the costs and simplify things. However, I actually want to support 2 vehicles long term so the extra 10 amps with the 'smart' chargers is where I ..., Smart Management Modules. Generac’s Smart Management Modules allow for more coverage with a smaller generator through smart load management. Get more coverage with less when you use Generac’s power management option. WIRE-FREE TECHNOLOGY Increased affordability with wireless modules, lowering installation cost and providing the …, Hmmm, the only time iv seen the load shed module fry like that were the original versions that didnt have the standoffs on the back. I see yours had the standoffs. Does your switch have the stick on plastic insulator pad behind the load shed module. Its attached to the switch box itself. A kind of insulator. The coils can fry under 2 conditions., LED ON = LOAD CONNECTED LED FLASH IS = LOAD SHED LED FLASH as = 30 MIN LOCKOUT LED FLASH = GEN LOAD LOCKOUT LED OFF = NO MODULE POWER TEST Prevents cad from operating when system is operating under generator power. Disables contactor output for a specified time. Provides module status with easy viewing through the external viewing window, Oh7376a I have an available extra original mounting block to hold the Generac OH7376A Load Shed Controller Module. I also have 2 extra OH7376A units with mounting blocks included. Frank, I just sent you a PM. Model 5875, Nexus controller, 999cc Engine, 20kW LP, 2011., The Cummins Load Shed Power Management Kit is compatible with Cummins RS13, RS17, and RS20 Air-Cooled Generators. The Load-Shed Kit allows the generator system to disconnect and reconnect heavy loads as required to prevent generator overloads. Multiple features make this kit one of the best available power management options on the market., Load shed module blew up. Automatic/Manual transfer switch repair, wiring & troubleshooting questions ... Generac tech for over 12 years. I'm here to help! "The only source of knowledge is experience" -Albert Einstein ... Off Topic; ↳ Introduction; ↳ General Discussion; Generator & Parts Garage Sale;, Product Description. Generac Assy Module- Pwrcell Ats Controller V2 A0001243729. Model: G0080060. With the PWRcell ATS Controller, turn a standard Generac ATS into a PWRcell-ready ATS with generator integration capabilities. Compatible with single-phase RXS and CXS series Generac automatic transfer switches between 100A - 200A, both service ..., Generac 16kW Guardian whole home generator with load shed, full cycle, Load shedding is a good way to protect the power grid from permanently failing. When a large demand occurs, it serves as a warning to the power company. It tells them to increase the load capacity and efficiency to meet the demand. It also serves as a reminder to consumers that they should use electricity more efficiently., Lock-out feature - Smart Management Modules feature a lock-out system, which permits blocking of specific loads only when using generator power, allowing for the important loads to be powered more often. Externally visible LED status, view load status without opening the electrical box for convenient management of power during an outage