Honda generator wont start

The tech said it creates something along the lines of a "electromagnetic gate" the resistance in pulling starting is created from parts of the generator acting like a magnet. Hope this helps some of you. The part was very expensive by the way, I think it was either $400 or $600. Share. Improve this answer.

Honda generator wont start. The propane is used in place of gasoline, which is what most generators use. Check to make sure there are no leaks in the tank. If the generator runs then shuts off it may be a temperature issue. Check the oil level and air filter. Examine the device connected to the generator. Open the generator (ensure it is off) and check to make sure the ...

Download. Owner's Manual EZEL 1000001 - 9999999. Download owners manuals for Honda generators EZ Series.

Honda Generator EU6500is white smoke and won't start up. My generator was run with very slow rpm and white smoke then shut down after few second. Basically it had no issue before but it happened after sitting for few months. I have replaced with new carburetor, spark plug and new air filter but the symptom were the same.Runs approximately 9.8 hours @ 50% load (6.2 gal.) Keeps you working, all day long. The EB6500 runs approximately 9.8 hours at half load and 6.4 hours at full load. 3 year residential warranty. You can rest easy, knowing your generator is covered from top to bottom for 3 full years. Hanger kit/lifting eye standard. Easy folding handles.Apr 7, 2022 · Possible reasons not to start: Check the oil level. These generators have a low oil level sensor that won't allow you to start it when there is no enough oil in the engine. Oil DOES evaporate (and leak) when left for several months. There is a specific blink pattern of the control light that I don't remember, but is listed in the manual. 6. Check for Loose Connections: Make sure that all connections in the generator are tight and secure. Loose connections can cause the generator to backfire, especially in the electrical system. Check all electrical connections, including the battery cables, spark plug wires, and alternator connections. 7.This 1997 Honda generator needed a new carburetor and is usually an easy fix. Deciding to purchase a cheap non OEM carburetor for $20 instead of the OEM $200...

The Honda EU3000iS inverter generator offers 3000 watts of power with the convenience of electric start. The EU3000 portable generator is ideal for home, RV, and more. Go. ... clean power in a smaller, lighter package. The precision of Honda's inverter technology ensures our inverter generators produce power that is as reliable as the power you ...Thankfully, it’s generally an easy fix if you’ve been taking care of your unit. As a general rule, a generator will be hard to pull start due to hydrolock in the cylinder, a malfunctioning recoil start assembly, a damaged flywheel or flywheel keys, the piston is seized, or the compression release is broken.The following steps will help to keep rust and corrosion from impairing your generator's function and appearance, and will make the engine easier to start when you use the generator again. Page 63 STORAGE Adding a Gasoline Stabilizer to Extend Fuel Storage Life When adding a gasoline stabilizer, fill the fuel tank with fresh gasoline.A Troy-Bilt mower won't start when there is a fuel restriction due to clogged filters and fuel lines, a dirty carburetor, a bad gas cap, a bad battery, a faulty spark plug, a bad switch, a bad ignition switch, or starter solenoid. Keep reading for additional items that cause a starting problem. Remove the spark plug wires before you begin ...if your generator will not start, I will take you through the steps needed to get it running again. It could be anything from something as simple as no fuel,...

The Black Max Generator leaks gas. The carburetor bowl has a gasket underneath it to prevent any fuel leakage from occurring. If you want to fix the issue caused due to the leaking of fuel from the carburetor’s bowl, then you could try replacing the gasket on the underside of it. One or more of the carburetor gasket (s) may be missing or damaged.1. Get a spray can of starter fluid. Remove the air cleaner from the engine and give a 1-2 second shot of fluid into the air intake, then immediately try to start the engine. If it stumbles or even runs briefly then you know the ignition system is functioning and you have a fuel delivery problem.Troubleshooting Steps for Honda Generator Power Problems. If your Honda generator is struggling to produce power without the choke, there are several troubleshooting steps you can take to diagnose and fix the issue. By following these steps, you can identify the root cause of the problem and implement the appropriate solution. Step 1: Check the ...You need to know that if you just acquired a new Honda eu3000 generator, you will have to hook up the battery. It does come with a battery, but it is disconn...Any time you have a starting problem start with the simplest and work your way back. Battery-fire-fuel. ensure the battery is fully charged, if it still doesn't start check to see if it has fire getting one of the little spark test lights is easiest, but if not, a screwdriver in the end of the spark wire and hold screwdriver about 1/4 inch from ...paulr44. 1737 posts · Joined 2008. #3 · Dec 23, 2008. I agree it's a fuel starvation issue, but want to point out that SOME, but not all by any means, of Honda's generators had a vacuum-operated fuel valve between the carb. and the tank, AND, some larger units had a main jet shut-off solenoid. Either of these devices being faulty would ...

Good morning beautiful memes for her.

If that is so, then your generator will refuse to start. You can prevent this by emptying the fuel tank and carburetor. To check if this is the reason, check if the fuel is reaching the carburetor by inspecting the position of the fuel valve. If the valve is closed, then the fuel won't flow to the carburetor. You can open the valve.EU3000is generator will not start with the key but will start with the pull cord. Battery is good. The starter motor turns over fine. There is spark at the plug. But it will not start. Mechanic's Assistant: Have you checked the battery, particularly the terminal connections? Are they corroded? The battery has 12.7 volts and the terminals are ...This is the official service website for Honda, Power Products, Marine, General Purpose Engine & DC Power unit, GX200. ... Engine will not start: Possible cause: Spark plug wet with fuel (flooded engine). Dry and reinstall spark plug. Start engine with throttle lever in MAX. position. How to do;It does not matter if your propane generator won't start or your Honda generator won't start. Whatever the case, trouble starting generators is a common enough problem. So are the solutions. Our list above should help you figure out what is wrong. But, you tried everything on the generator will not start troubleshooting list.The purpose of this valve is to automatically shut off the flow of propane if the engine stops for some reason. You have to override this shutoff until the engine is up to speed. An electric cutoff may be operated from an oil pressure switch. A vacuum cutoff will have a line to the intake manifold. Keith.

The plug gap should be between 0.028-0.031 inches (0.7-0.8 mm.) To reinstall, screw the plug in by hand to keep it from cross-threading. Tighten down the plug with the plug socket or wrench, tightening 1/8-1/4 of a turn once the plug is seated. If the plug is new, tighten it 1/2 turn to ensure the plug washer makes a tight seal.If a problem should arise, or if you have any questions about the generator, consult an authorized Honda dealer. B The Honda generator is designed to give safe and dependable service if operated according to instructions. ... The generator may be hard to start if a load is connected. CIRCUIT BRhAKERS 7 . 4. STARTING THE ENGINE 1. Turn the fuel ...1. Hold all three buttons ('A', 'Start', and 'Stop') down at the same time for about three seconds until the light blinks orange. 2. Lift up and repeat a second time until the light blinks orange again. 3. Lift up and repeat a third time until the light turns green. Once green, it is reset and ready to pair.1. Weak Battery. If your Passport's engine won't crank or cranks very slowly, then the most likely culprit is a weak or dead 12v battery. Investigating more closely and doing a battery voltage test will clarify whether the starting problem is due to the battery. A test can be done to measure the voltage between the battery poles, check the ...How To Repair A Honda EU2200i Generator That Won't Start. ToddM. 2.09K subscribers. Subscribed. 89. 7.8K views 6 months ago. This video shows how to …My Honda Generator EB3000c won''t start. It is 3 1/2 years old and has only run for 8 strait hours during a hurricane in - Answered by a verified Technician. We use cookies to give you the best possible experience on our website. ... My Honda Generator EB3000c won''t start. It is 3 1/2 years old and has only run for 8 strait hours during a ...Links to products I have in my tool bag.Compression tester. https://amzn.to/2NMgezeSpark Checker. https://amzn.to/3bnXjmAHonda Generator EU1000 won't star....This is the official service website for Honda, Power Products, Marine, General Purpose Engine & DC Power unit, GX200. ... Engine will not start: Possible cause ...Summary of Contents for Honda EX1000. Page 3 Thank you for purchasing a Honda generator. We want to help you get the best results from your new generator and to operate it safely. This manual contains the information on how to do that; please read it carefully. EX1000 This owner's manual describes the operation and maintenance of the EX650...Thankfully, it's generally an easy fix if you've been taking care of your unit. As a general rule, a generator will be hard to pull start due to hydrolock in the cylinder, a malfunctioning recoil start assembly, a damaged flywheel or flywheel keys, the piston is seized, or the compression release is broken.01 - Spark Plug. Inspect the spark plug for signs of wear or damage. If the porcelain insulator is cracked, an electrode is burned away or damaged, or there is heavy carbon buildup at the electrode, replace the spark plug. To determine if the spark plug is defective, use a spark plug tester. You should see a strong spark between the tester’s ...Are you looking for the best deals on a Honda Civic? With so many options available, it can be difficult to know where to start. Fortunately, there are a few tips and tricks that c...

We've been unable to start our Honda eu2000i generator this last week. What we've done so far: oil change, new spark plug, cleaned carb, broke down and bought new carb, cleaned filters. It sounds like it is trying to start but can't. This rig is a decade or so okd, always gets oil changes, filter cleaning, carb cleaning regularly.

Keep the spark plug a few inches away from the engine's case; if there are intense blue sparks, your spark plug is working fine. You do not need to change it. Ignition Coil: If your generator is still not starting after checking the spark plug, there may be some problem with your generator's ignition coil.paulr44. 1737 posts · Joined 2008. #3 · Dec 23, 2008. I agree it's a fuel starvation issue, but want to point out that SOME, but not all by any means, of Honda's generators had a vacuum-operated fuel valve between the carb. and the tank, AND, some larger units had a main jet shut-off solenoid. Either of these devices being faulty would ...Locate the yellow wire on the crankcase. Follow this wire until you locate the green quick connect. Grasp the two ends firmly and separate the two wires at the connection. Start the engine and allow it to run for 15 minutes before reconnecting the sensor. If this not does remedy the issue, please proceed below:17871 posts · Joined 2010. #2 · May 16, 2011. welcome to the forum. 1st thing i would do is check the compression both hot and cold (see if it differs) 2ndi would makesure there is no restrision in the muffler. 3rd id change the sparkplug (if cracked it can stop working when it gets hot it expans) 2000 foreman 450 es-s.It does not matter if your propane generator won't start or your Honda generator won't start. Whatever the case, trouble starting generators is a common enough problem. So are the solutions. Our list above should help you figure out what is wrong. But, you tried everything on the generator will not start troubleshooting list.Hi, Honda Generator. Model EM5000SXA. Frame No. EM5000S-1008277. Engine No. GC05-1050746. The choke had been sticky and reluctant to release despite being lubed when it was serviced last year. I took it apart and made sure all the parts moved freely. The auto-choke vacuum diaphragm looked to be in good shape.The most common fuel issue with the Honda generator EU3000is is a clogged fuel filter . If the generator is not getting enough fuel, it may start and then stall. To fix this issue, clean or replace the fuel filter. Another fuel issue is a clogged carburetor. If the carburetor is clogged, the generator may not start or run poorly.Mar 19, 2024 ... Thanks for tuning into another Otto's Small Engine Video! In this video I go about diagnosing a Honda EU 1000i Inverter Generator that came ...Step 4: Fill Up with New Gasoline. Once you clean out the generator tank and make sure there is nothing remaining from the previous gasoline. Now it is time to fill up with new fuel. Make sure that there are not any impurities in the new gasoline. Or it could also cause problems with the generator later on.2). Faulty Ignition Coil. When you start the engine, the ignition coil sends the voltage to the spark plug. A faulty ignition coil can prevent the spark plugs from generating a spark. Test the spark plug first. If it works, turn your attention …

Julian's meadville pa.

Rouses lafayette weekly ad.

If your generator still won't start, check the spark plug. Remove the spark plug and inspect it for any obvious damage. If the porcelain part is damaged, the spark plug won't work. Carbon buildup is another common sparkplug problem. If the spark plug is black and sooty, use a small piece of sandpaper to clean the terminals.Troubleshooting Steps for Honda Generator Power Problems. If your Honda generator is struggling to produce power without the choke, there are several troubleshooting steps you can take to diagnose and fix the issue. By following these steps, you can identify the root cause of the problem and implement the appropriate solution. Step 1: Check the ...165 posts · Joined 2007. #1 · Oct 25, 2008. This Mulitquip 3500 generator has a Honda that won't run at full throttle without the choke applied about half way. I noticed this solenoid mounted on the bottom of the float bowl, I pulled it out and cleaned out the main jet. Both parts are clean and the engine will idle fine.1000w Honda generator wont stay running for more than a few 1000w Honda generator won't stay running for more than a few minutes, dies, and won't start again until it sits for a few hours. The generator is on level ground, oil level is full, freshly cleaned ga …Honda generator 6010 won't start by remote: lkghudson: Class A Motorhome Discussions: 1: 10-02-2014 03:32 AM: HELP? Question regarding a Honda EV6010 Generator: hbpaints: RV Systems & Appliances: 2: 08-20-2014 02:39 PM: Honda 3000i remote start: Bushman512003: iRV2.com General Discussion: 3: 09-23-2010 11:48 AM: Honda 2000 generators won't ...Now the other thing you can do, get a plastic tote from a store, set the genset inside or cover it with the tote. Use a 30-40 max watt light bulb on a thermostat that turns on the lamp at anything less that 55* F. Just make sure you cut a small vent hole for the gas vapor to escape, an it should start as normal.However, the Honda EM5000S generator is renowned for the fuel filter becoming clogged prematurely. In this instance, it will cause a number of problems, including difficulty, in starting the engine, turning it off unexpectedly, power performance, and misfiring. Many have commented that the primary issue is that the factor filter installed is ...If the recoil starter assembly is defective, the engine won't start. Remove the starter assembly and inspect it to determine if it is working properly. When you pull the starter rope, tabs extending from the pulley and cam should grab the hub on the engine, causing the engine to turn. When you release the rope, the tabs should retract and the ...One of the most basic reasons why your Honda generator won’t start is an empty fuel tank. It may sound obvious, but sometimes we overlook the simple things. Before assuming there is a technical problem, make sure your generator has an adequate fuel level. Check the fuel gauge and fill the tank if it is empty.Owner's Manual EA1 1000001 - 1099999. Owner's Manual EA1 1100001 - 1139795. Owner's Manual EA1 1139796 - 9999999. Owner's Manual GX360 1000001 - 1099999. Download owners manuals for Honda generators ES Series.Replace a faulty spark plug. Sometimes a faulty spark plug prevents your generator from starting altogether. Other times, the generator starts but won't stay running for more than a few minutes. If a faulty spark plug is the cause of the problem, clean or replace it. Firstly, remove the spark plug from the generator.http://goo.gl/9fSJwf click link to get the entire carburetor.In this video I take two Honda GX160 5.5HP engines and combine the parts to try to get one work... ….

This 1997 Honda generator needed a new carburetor and is usually an easy fix. Deciding to purchase a cheap non OEM carburetor for $20 instead of the OEM $200...• The generator produces enough electric power to cause a serious shock or electrocution if misused. • Using a generator or electrical appliance in wet conditions, such as rain or snow, or near a pool or sprinkler system, or when your hands are wet, could result in electrocution. Keep the generator dry.2). Faulty Ignition Coil. When you start the engine, the ignition coil sends the voltage to the spark plug. A faulty ignition coil can prevent the spark plugs from generating a spark. Test the spark plug first. If it works, turn your attention …What to Do. To determine whether the oil sensor is the cause of all the starting problems you are facing, disconnect it from the motor's crankcase and try restarting the generator. If your recreational vehicle's generator starts when the sensor is disconnected, it a clear sign that the sensor is malfunctioning.The most common fuel issue with the Honda generator EU3000is is a clogged fuel filter . If the generator is not getting enough fuel, it may start and then stall. To fix this issue, clean or replace the fuel filter. Another fuel issue is a clogged carburetor. If the carburetor is clogged, the generator may not start or run poorly.If your generator is running but there is no power, the most likely cause is a lack of fuel, a faulty spark plug, a dirty air filter, or a malfunctioning starter. To troubleshoot the issue, you should first check the fuel level and replace the spark plug, clean the air filter, and check the starter. If these steps do not fix the problem, then ...Where the generator choke is concerned, you don’t have much to remember. Just keep these three points in mind: 1). Before you start a cold engine, you have to move the choke to the ‘ON’ position. This means the choke is closed. You should only move the choke to the ‘OFF/Closed’ position when the engine warms up. 2).MSRP. $2799*. 5000 watt 120/240V generator with CO-MINDER™. Provides 7,000 watts for 10 sec to start larger equipment. Powers fridge, furnace, well pump, and much more. Long run time - up to 10.5 hrs. Electric start. Honda My Generator app + Bluetooth ® capability. CO-MINDER: advanced carbon monoxide detection system. Honda generator wont start, Hi, Honda Generator. Model EM5000SXA. Frame No. EM5000S-1008277. Engine No. GC05-1050746. The choke had been sticky and reluctant to release despite being lubed when it was serviced last year. I took it apart and made sure all the parts moved freely. The auto-choke vacuum diaphragm looked to be in good shape., A Generac generator won't start due to an empty fuel tank, old gas, plugged fuel filter, clogged fuel line, dirty carburetor, bad spark plug, faulty ignition coil, plugged air filter, plugged spark arrestor, incorrect engine oil level, bad dial, faulty starter recoil, or bad starter switch. Take caution when making repairs on your equipment ..., Apr 29, 2022 ... After the video I turned the RPM down to 3400. Thanks for the suggestions. I should have caught that. First Thumbnail Try LOL Here is my ..., One of the possible solutions if your Honda ES 6500 generator will not start is the choke solenoid, Gentrax Generator Problems. 1 . Generator Won't Start. The most common reason why a Gentrax generator won't start is due to an issue with the fuel system. This can typically be attributed to stale fuel, a clogged fuel filter, or problems with the carburetor. Other potential causes could be associated with the battery or the spark plug., Honda 2800 watt generator review. This is a comparison review between the Honda EG2800i and EB2800i inverter generator. Both generators have 2800 starting an..., Push and hold the center button, choke, until it starts (when cold). Press and hold the top button until it starts when warm. Usually just and second or 2. Press the red button on the bottom until the genny dies. I have a small low watt night light that I use for an indicator light., MAKE SURE LOCATION IS ON. With location on, it paired up. Need to start the gen when you try to pair up. Revising to three stars. Worthless, won't pair through the app. Tried twenty times, have to enter the s/n every time, stop and start the generator each time. Can see the generator appear as EMA- in the phone's Bluetooth for 30 seconds., Honda Generator won't start after it warm. Jump to Latest Follow 3K views 9 replies 10 participants last post by dwclark1974 Aug 19, 2023. T. tcbob Discussion starter 2 posts · Joined 2022 Add to quote; Only show this user #1 · Jun 15, 2023. I have a Honda EU3000 generator that will run fine when it's cold, but after it gets warmed up and run ..., The Honda My Generator Bluetooth® App operates within a 75-foot line of sight, allowing the user to start (electric start models only) and stop the generator; monitor a range of information, such as output power, engine operating hours, oil life, fuel level (EU7000iS only), estimated run times based on power usage; as well as receive warnings ..., Honda Specific: General, Tech, & Perf. ATV Forums. Wont start and backfiring! Help! Purchased a new battery (sealed) for my 98ES in October and ran it a few times during hunting season with everything ok. (my new Honda motorcycle has been getting most of the attention) Put it on a charger last night and this morning it would not crank!, Problem 1: Generator Won’t Start The first problem you may have with your Honda generator is that the generator just doesn’t want to start. This may be caused by several factors including engine faults, low oil level, a blockage in the air filter or if the wrong type of fuel has been used., Well-known member. My trailer has a Broughton A3400 13500BTU AC with a soft start. The specs say 14 amps cooling and max amps of 15.5. A Hughes Watchdog electrical protector is hardwired in the system. When I try to run the AC on a Honda 2200i generator, the Hughes cuts the power when the compressor tries to start. Nothing else is on., Generator won’t start. 8 possible causes and potential solutions . Learn More. Featured Video. Video. 03:14. Generator won't stay running. 3 possible causes and potential solutions . ... Shop by Popular Honda Generator Models. E1500K4A E2500K4A E300K1A E300K2A E300K3A E3500K1A. EB11000A EB2200XA EB3500XA EB5000XA …, Feb 18, 2024 · That would indicate after a night of charging that maybe the battery isn't taking a high enough load. Which might explain the push button - but not a pull start as I've seen video of pull starts with batter disconnected). It's going to be another full week until the Honda guy can look at it. , The tech said it creates something along the lines of a "electromagnetic gate" the resistance in pulling starting is created from parts of the generator acting like a magnet. Hope this helps some of you. The part was very expensive by the way, I think it was either $400 or $600. Share. Improve this answer., Possible causes for a Honda generator not starting are: An engine fault, e.g. it has seized. The engine oil level is too low. There isn't enough fuel in the tank, the wrong type of fuel has been used and/or fuel has been left sitting in the tank for a long time without use. A problem with the fuel injector (s), e.g. it's clogged., 1000w Honda generator won't stay running for more than a few minutes, dies, and won't start again until it sits for a few hours. The generator is on level ground, oil level is full, freshly cleaned gas tank, clean fuel filter, fuel pump seems to work fine, doesn't smell like it is flooding, gas cap vent is open., My Honda Generator EB3000c won''t start. It is 3 1/2 years old and has only run for 8 strait hours during a hurricane in 2006. I have occasionally started it up throughout the year but yesterday it would not start. It has normally started real fast but not now... Please advise., Any time you have a starting problem start with the simplest and work your way back. Battery-fire-fuel. ensure the battery is fully charged, if it still doesn't start check to see if it has fire getting one of the little spark test lights is easiest, but if not, a screwdriver in the end of the spark wire and hold screwdriver about 1/4 inch from ..., The EM6500 is designed primarily for home backup power. It has electric start and Bluetooth capability, allowing it to connect to the Honda My Generator app for remote start and stop, plus operation monitoring and other capabilities. The EB6500 is designed primarily for construction / industrial use., To start the Yamaha generator through the battery: • Put on the fuel valve and press in the generator choke. • Then ignite the generator through the ignition key and switching the key to the ON position, then START to power the engine. • Press the choke again to enable the generator to run efficiently. • You can put on the Eco-mode when ..., Connect the black or white one to the ground battery terminal of the generator. Connect your light to the generator and turn it on. Connect the red brush cable with the red cable from your 12+ vault battery. Hold both against the voltage generating terminal for a few seconds. Remove the battery wire., We've been unable to start our Honda eu2000i generator this last week. What we've done so far: oil change, new spark plug, cleaned carb, broke down and bought new carb, cleaned filters. It sounds like it is trying to start but can't. This rig is a decade or so okd, always gets oil changes, filter cleaning, carb cleaning regularly., No Start Honda Generator, Quick and Easy Fix! Honda EG1400 Generator, Flea Market Generator, $40 Flea Market Generator, $40 Honda Generator, Generator carb i..., Solution. You’ll need to inspect the integrity of the pulley by removing the starter and checking any damage on its parts. If it is broken or cracked, you need to replace it with a new one in the following steps: Pull the pull cord completely out of the pulley. Insert a screwdriver in the pulley to lock it in place., Honda generators won't start when there isn't sufficient air, spark, and fuel. This may be due to a lack of fuel, plugged fuel filter, clogged fuel line, dirty carburetor, plugged air filter, clogged spark arrestor, bad spark plug, faulty ignition coil, bad gas cap, or low engine oil level. Honda generators with an electric start may have a ..., How to check fuel pump If honda generator won't start eu70is If the Honda generator does not startthere may be a problem with the fuel pumphow to check the f..., Honda EB3000C has a dead battery: even though most Honda generators last for around ten years, the battery doesn't necessarily last as long.If you own an RV, you likely use your generator often and wear out the battery. Honda EB3000C has insufficient fuel: If you don't have enough fuel in your Hyundai EB3000C generator, it won't turn on.So top off your fuel and see if this helps., A Honda generator may start and then die due to a plugged air filter, wrong choke setting, clogged fuel line, plugged fuel filter, dirty carburetor, bad gas cap, dirty spark plug, faulty ignition coil, low engine oil level, or old gasoline. Follow all safety precautions listed in the Honda operator’s manual., Problem- Honda Generator won't start Solution 1- Check Spark Plug. When the generator won't start firstly you Inspect the spark plug, use a spark plug tester. if the spark plug is faulty, change the spark plug. Solution 2- Carburetor. A filled carburetor is usually due to the fuel leaving the generator for a long time. Over time, some of ..., Check The Battery/Fuses. If your battery is too low, your generator probably won't start. Make sure you have adequate voltage for your generator to start by measuring the voltage output of its battery with a multimeter. Consider obtaining a jump-start from another car or attempting a flash generator with an external battery if you don't ..., If the recoil starter assembly is defective, the engine won't start. Remove the starter assembly and inspect it to determine if it is working properly. When you pull the starter rope, tabs extending from the pulley and cam should grab the hub on the engine, causing the engine to turn. When you release the rope, the tabs should retract and the ...