400 amp service wire size chart

what cable do I need for a 400 amp service 650 ft run and what transformer. On 2020-08-26 y Mike Lange . I am looking for underground wire size needed to run 1200 feet .. I would like a 30 amp 240 volt …

400 amp service wire size chart. Step 2: Pick the Appropriate Table: Based on the system configuration, refer to the appropriate table in the CEC to determine the wire size. Here are the relevant tables to consider: Table 1: Single free air copper conductors. Table 2: Three or fewer copper conductors in a raceway or cable. Table 3: Single free air aluminum conductors.

Example: 400 kcmil wire has a cross-section equal to 400 thousand circular mils. The key question kcmil wire size chart (which is the same as MCM wire size chart) answers is how many amps can a wire handle. The ampacity (how many amps they can carry) of wires depends on 3 primary factors, namely: Cross-section. This is denoted by kcmil or MCM.

A 1,000 kcmil aluminum or 600 kcmil copper wire is ideal for a 400-amp service. However, the wire to choose for the service panel may differ depending on certain factors, such as wire type and length. It’s important to understand the features of different wires to know which model to use for your 400-amp service.The ground wire for 600-amp service: When it comes to the ground wire, we will need 1-kcmil gauge wire of copper wire and Aluminum 2/0-kcmil wires. Aluminum wire for 600-amp service: Now the size of aluminum wire for 600-amp service is 2000 kcmil. Copper wire for 600-amp service: In this case, we always need to follow a rule of thumb.50 amp wire size chart50 amp wire size chart Cable gland size chart pdfWorking with wire. 400 amp service wire size chartHow many amps is #6 wire good for? National electrical code wire size chartWire chart dc amp gauge sizing copper charts.400 amps * .83= 332 amps conductor- which is necessary for the 400 amp service on a residence. You would have to de-rate 80% because of the number of …This DC wire size calculator will help you calculate the wire gauge automatically. Example: For 100 amp service, you will a wire with at least 125A ampacity. That means you will need a 1 AWG wire for 100 amps since it has 130A ampacity. Wire size chart. In this chart, you can find wire sizes for 1 amp, 10 amp, 20 amp, 30 amp, 40 amp, 50 amp, 60 ...When looking for a 200 amp service entrance wire size, you should consider the 3% allowable voltage drop by NEC standards. As a result, you need to use a much bigger wire size than the one for short-distance setups. In this case, instead of using a 2/0 copper wire, you should use 300 kcmil copper with only a 2.78% voltage drop.

Electrical wire: auto electrical wire sizes Wire size determining conversion table chart reply gm 150 amp cable size. 400 Amp Service Wire Size Chart - How to best 2022. How many amps of electricity does home use: Electric work: wire-size Code 42: selecting the correct gauge wires for your rc models. 200 amp service wire size chartNanowires and Carbon Nanotubes - Nanowires are wires with a very small diameter, and can be used to build tiny transistors for processors. Learn about nanowires and how nanowires w...Example: A 120/240-Volt, 3-Wire, single-phase electrical service for a single-family dwelling with a calculated load (from Article 220) of 98 amps, supplied by THWN copper overhead service entrance conductors. A 100 amp electrical service will be used to supply the 98 amp load for the single-family dwelling. 100 amps X 83% = 83 amps. This is ...For example, if you’re wiring up a 15-amp circuit, then your fuse should also be rated at 15 amps. The fuse rating for most car amplifiers is 10 amps. However, there are exceptions, with some amplifiers requiring a 20-amp fuse and others 12-amp fuses. If you want to know whether your car amplifier has a 12 or 20-amp fuse, check the label on ...This DC wire size calculator will help you calculate the wire gauge automatically. Example: For 100 amp service, you will a wire with at least 125A ampacity. That means you will need a 1 AWG wire for 100 amps since it has 130A ampacity. Wire size chart. In this chart, you can find wire sizes for 1 amp, 10 amp, 20 amp, 30 amp, 40 amp, 50 amp, 60 ...You'll need to consider wire strength and material when determining whether to use 2/0 AWG copper wire or 4/0 AWG aluminum or copper-clad wire. According to the NEC, these are the correct wire sizes for a 200-amp service: Service Rating (Amps) Copper (AWG) Aluminum or Copper-Clad (AWG) 100. 4. 2.18-, 16-, or 14-gauge wires for speakers. 16-, 14-, or 12-gauge wires for subwoofers. As with the power wire, the longer the run and the more current you're pushing through it, the larger size you should use. For example, if your amp is in the trunk and you're sending 100 watts to your front speakers, 14-gauge speaker wire is a good call. The Wire Size Calculator below will calculate the proper wire size for a circuit based on circuit amps, preferred (or available) wire insulation, conductor type and installation specifications. For more advanced considerations, use the Wire Size Calculator or the Advanced Wire Size Calculator.

Min. Wire Ampacity (100 ft away) = 125A × 1.2 = 150 Amps. That means that we need a wire with at least 150 ampacity to deliver 100 amp service 100 feet away. If you check the wire size chart (you have the link in the introduction), the #0 AWG wire (also known as 1/0 AWG wire) has 150 ampacity. That means that #0 AWG wire is the perfect size ...The best wire size for a 400 amp service is a 1000 kcmil copper wire or 600 kcmil Aluminum or Copper-Clad Aluminum Wire. This wire size will ensure the best possible service for your building. A certified electrician is necessary for handling these types of amperages and wiring.The branch-circuit is supplied by a 208/120 volt, 4-wire, 3-phase, Wye connected system. Step 1 - Size the overcurrent protection device in accordance with Sections 210-20(a) and 384-16(d). The first thing that we must do convert the nonlinear load from kVA to amperes:The signal and power coming out of your amplifier must not be impeded on their way to your speakers and subs. When you replace or run new speaker wiring, we recommend using: 18-, 16-, or 14-gauge wires for speakers. 16-, 14-, or 12-gauge wires for subwoofers. As with the power wire, the longer the run and the more current you're …Jul 23, 2019 · Case 1: 2500 ft., 15Amps, 120VAC, and the wire size calculator returns . 1 conductor per phase utilizing a 400 kcmil Copper conductor installed Direct Buried will limit the voltage drop to 2.95% or less when supplying 15 amps for 2500.0 feet on a 120 volt 1 phase system. OR . Case 2: 2500 ft., 15Amps, 240VAC, and the wire size calculator returns Most areas will not allow a 320 amp meter base for a 400 amp commercial service. Also, you will not be able to downsize the service conductors as in residential. If you parallel the service conductors, the minimum size is 3/0 copper or 250 aluminum for a 400 amp commercial service.

Dogs for adoption midland.

That’s why we use #6 AWG wire for 40 amp service 100 feet away. We also use #6 AWG wire for 40 amp service 150 feet away. When the sub panel is 200 feet away, however, we have to add 40% on top of the 50A minimum ampacity. That’s 70 amps. Even the #6 AWG wire is not sufficient here. For 40 amp service 200 feet away you need #4 AWG wire.This is a good goal to shoot for when sizing the conductors for an underground cable. The following are the maximum lengths of cable you can use while still maintaining a 3 percent voltage drop for the given wire size (AWG) and circuit voltage. As an example, for a 120-volt circuit, you can run up to 50 feet of 14 AWG cable without …400 amp service wire size chart. Table of underground electrical service cable sizes & ampsSize ground wire nec grounding 250 chart table conductor 66 equipment neutral 122 electrode grounded diy required lovely stackexchange electrical Nec underground 300 requirements buried inspectapedia amps ampacitySizing wire … 400; 280: 335* 380* 225: 270: 305: 400: 500 ... Max. size of Type UF is 4/0 AWG. ... service lateral conductors and feeder conductors that serve as the main power feeder Now we have to find a wire with 300A ampacity or more. If you consult the KCMIL list above, you can see that the 350 KCMIL wire is perfect for 200 amp service 100 feet away. That’s because it has a 310A ampacity. You can make a similar calculation for 50 feet (10% addition), 150 feet (30% addition), and 200 feet (40% addition), and choose the ...

The size of the wire is always the same in theory (we’ll cover how big a wire you need for a 60 amp breaker further on): 60 amp wire size is either 6 AWG or 4 AWG wire (AWG stands for American Wire Gauge; standard wire sizing is the US) for 220V voltage. An amateur will use a 6 AWG wire size for 60 amp 220V. A professional will always use 4 ... Use a wire size calculator or chart to look up the recommended wire gauge based on the amperage of the circuit. ... You need 350 kcmil copper wire for a 400 amp 120 ... This wire size calculator will calculate the appropriate wire gauge for a circuit based on amps, voltage, distance, and load. This website provides a wire size calculator, voltage …Final Thoughts. Selecting the accurate ground size is important for the installation of a 400 amp service panel. The NEC comes in handy in this case as they provide the appropriate grounding size required for a 400 amp service panel which can be of 1 awg to 3 awg. An electrician will be able to choose properly. By.The best wire size for a 400 amp service would be 1,000 kcmil aluminum wire or 600 kcmil copper wire. The wire size can change based on factors like the wire material, distance, voltage drop, temperature, and overhead and underground power lines.For a 400 amp service with aluminum, aim for a 1,000 kcmil wire. And for the ground, a 1 AWG aluminum wire should do the trick. So here’s a quick recap for you: …If you are installing a 400 amp service then you can use conductors based on the table in art. 310 ... a calc I would use the 83% for the 200 amp service for the house and 200 amps for the shop which means you could use a wire rated for 366 amps . Reactions: augie47. electrofelon Senior Member. Location Cherry Valley NY, Seattle, …For a 400 amp service with aluminum, aim for a 1,000 kcmil wire. And for the ground, a 1 AWG aluminum wire should do the trick. So here’s a quick recap for you: Copper: Go with 600 kcmil for the main wire and 3 AWG for the ground. Aluminum: Opt for 1,000 kcmil for the main wire and 1 AWG for the ground.

Oct 9, 2011 · 230.42 would apply to the service neutral, and would require a #3 THHN. As I see it, my steps in solving this problem for the service conductors are 1. Determine the minimum conductor size for 100A per 310.15(B)(16). (#3 CU THHN) 2.

The branch-circuit is supplied by a 208/120 volt, 4-wire, 3-phase, Wye connected system. Step 1 - Size the overcurrent protection device in accordance with Sections 210-20(a) and 384-16(d). The first thing that we must do convert the nonlinear load from kVA to amperes:400: 280: 335: 380: 225: 270: 305: 400: 500: 320: 380: 430: 260: 310: 350: 500: 600: 355: 420: 475: 285: 340: 385: 600: 700: 385: 460: 520: 310: 375: 420: 700: 750: 400: 475: 535: 320: 385: 435: 750: 800: 410: 490: 555: 330: 395: 450: 800: 900: 435: 520: 585: 355: 425: 480: 900: 1000: 455: 545: 615: 375: 445: 500: 1000: 1250: 495: 590: 665: 405 ...The 40 amp wire size at 50 feet sub panel is 50 A x 1.1 = 55 amps. Wire size at 100 ft = 50 A x 1.2 =60 amps. Wire size at 150 ft = 50 A x 1.3 = 65 amps. 40 amp size of wire at 200 feet = 50 x 1.4 = 70 amps. Then you go to the awg wire size chart table and look for their wire sizes. Type of wire or conductor usedThhn mm2 400 amp service ground wire size Wire size chart for amps. ... Thhn wire sizes tableThhn wire sizes table 400 amp service wire size chartWire gauge chart amp amperage length wiring sub battery toyota 4runner size vs capacity charts wires feet selecting car power. Check Details Wire size for 20 amp 220v. Thhn wire sizes …400 amp service wire size chart - Hear Chronicle Picture Galleries. Check Details. Electrical Wire Sizes (Gauges) For Your Home. 20001 Brownstown Center Dr Brownstown Charter Twp Mi 48183. 200 Charter Colony Pkwy. Random Posts. 2020 F 250 Towing Capacity Chart; Baby Food Chart 4 Months; Number Chart 201-300 Printable; …Step 2: Pick the Appropriate Table: Based on the system configuration, refer to the appropriate table in the CEC to determine the wire size. Here are the relevant tables to consider: Table 1: Single free air copper conductors. Table 2: Three or fewer copper conductors in a raceway or cable. Table 3: Single free air aluminum conductors.120/240 volt, 3 wire, single phase service-entrance conductors, service lateral conductors and feeder conductors that serve as the main power feeder to a dwelling unit and are installed in raceway or cable with or without an equipment grounding conductor. For application of this section, the main

Fruit pectin thc.

I 40 accident arizona.

NEC 220-2 Code: This code suggests that a conduit wire’s maximum load (30 amps) should represent 80% of the wire ampacity. NEC 310-16 Code: This code determines the wire size for 30 amps of service at a distance.Add 20% to the wire’s ampacity for every 100 feet away from the sub panel. The 220-2 code will check the wire size usually …Mar 13, 2013 · Table 310.15(B)(7) Allows me to use 400kcmil USE copper for a 400 amp underground residential service which in table 310.15(B)(16) would have an amperage rating of 335 amps. Now using the amperage rating of 2/0 USE, which is 175 amps, and running it in parallel would give a total ampacity of 350 amps. I think this really comes back to people knowing they can use one set of 500s for 400 amp OCPDs so they figure two sets of 500s get them to an 800 OCPD. …I am putting in a 320 Amp Meter housing, with either a 400 Amp Panel or 2-200 Amp panels, and have to run the service laterals 200 feet....not sure how to do this most efficiently...? Am not sure that 400 Amps are needed, but the owner hopes to add a shop later, and already has two large A/C units and two double ovens … For a full chart of wire size by amp rating, visit this website. What Is The Cost To Upgrade To a 400 Amp Service? The cost to upgrade to just a 400 amp panel will set you back between $2000 to $4000. Things to consider in the cost of your upgrade include: Replacing your current panel box with a larger one ; Hiring a licensed electrician. 800 amp feeder you want to use #3/0 which is a 200 amp conductor 800/200=4 sets. Switch to 600 kcmil which is a 420 amp conductor 800/420=1.9= 2 sets. In your example you want to use 2 sets for 400 amps that means that each set needs to have an ampacity of 400/2=200 amps or minimum size of #3/0.To calculate the size of the circuit breaker needed, we have to multiply the amp draw by 1.25 factor like this: Minimum Circuit Breaker Size = 12.5A × 1.25 = 15.63 Amps. We can’t use a 15A breaker because the breaker ampacity should be at least 15.63A.400 Amp Service Wire Size Chart - How to best 2022. What size service entrance cable for 200 amp / residential service Selecting the proper wire size Sizing ground wire. Nec service entrance wire size chart. Openings & wire sizes — unified screening & crushingWire electrical size table cable sizes service ampacity determining …400 amp service wire size chart. Electrical cable sizes chartHome charging wiring guide – teslatap How to install a subpanel / how to install main lugDetermining wire size. Jetta akinsWire wiring sizes charging types guide chart current wires use ampacity conduit range Chart wire size subpanel lug sizes breaker circuit feet rating ground … Min. Wire Ampacity (100 ft away) = 125A × 1.2 = 150 Amps. That means that we need a wire with at least 150 ampacity to deliver 100 amp service 100 feet away. If you check the wire size chart (you have the link in the introduction), the #0 AWG wire (also known as 1/0 AWG wire) has 150 ampacity. That means that #0 AWG wire is the perfect size ... ….

The AWG sizes for aluminum electrical wires are shown in the first chart, ranging from 4/0 to 12 AWG. These are regarded as smaller wires since they have a 180A median ampacity. Aluminum kcmil wires are available in the following gauges: 250, 300, 350, 400, 500, 600, 700, 800, 900, 1000, 1250, 1500, 1750, and 2000 kcmil.Brake light wiring can be a bit tricky, but it's doable. Learn how brake light wiring works at HowStuffWorks. Advertisement ­Brake lights serve a simple but important function — th...Two sets of 500 is under 800 amps it takes two sets of 600 to use an 800 amp breaker. Keep in mind at 800 amps or more 240.4(B) does not apply and you cannot round upThe best size of wire for 150 amp is 1 AWG copper or 2 AWG aluminum or copper-clad aluminum. If the temperature is around 194°F, use a 3 AWG aluminum wire gauge. The size of the wire should be around 1-1/4th inch wide. The right size for hot and neutral wires is 1 AWG copper or 2 AWG aluminum. For the ground wires, it is 6 AWG …This chart displays the size of a ground conductor for a circuit based on the ampere rating of the circuit protection devices. Toggle navigation WireSizeCalculator.net. ... 400: 2500: 350: 600: 3000: 400: 600: 4000: 500: 800: 5000: 700: 1200: 6000: 800: 1200: Note: View wire size charts from the list below. Maximum Allowable Ampacities for Conductors in …Dec 26, 2020 · Most areas will not allow a 320 amp meter base for a 400 amp commercial service. Also, you will not be able to downsize the service conductors as in residential. If you parallel the service conductors, the minimum size is 3/0 copper or 250 aluminum for a 400 amp commercial service. Despite popular belief, there are no standard wiring colors for each wire in a car. The specifics of the wire coloring are dependent on the make, model and even year of the specifi...Instead of throwing away or storing your old Linksys router, set it up as a switch, also known as a repeater. In doing so, you have the ability to hard-wire seven computers to your... 400 amp service wire size chart, Use a wire size calculator or chart to look up the recommended wire gauge based on the amperage of the circuit. ... You need 350 kcmil copper wire for a 400 amp 120 ..., 1 AWG copper wire for 125 amp service. This wire has 130A ampacity; more than the minimum required 125A ampacity. 2/0 AWG aluminum wire for 125 amp service. This wire has 135A ampacity; more than the minimum required 125A ampacity. Note on 125 amp breaker wire size: For breakers, we use the 80% NEC rule. That means that a 125A breaker can only ... , Table 310.15(B)(7) Allows me to use 400kcmil USE copper for a 400 amp underground residential service which in table 310.15(B)(16) would have an amperage rating of 335 amps. Now using the amperage rating of 2/0 USE, which is 175 amps, and running it in parallel would give a total ampacity of 350 amps., The branch-circuit is supplied by a 208/120 volt, 4-wire, 3-phase, Wye connected system. Step 1 - Size the overcurrent protection device in accordance with Sections 210-20(a) and 384-16(d). The first thing that we must do convert the nonlinear load from kVA to amperes:, NEC 310-16 Code. This determines what size wire for 30 amp service at a distance. Usually, you have to add 20% to the wire’s ampacity for every 100 feet away from sub panel. The first step in checking what size wire you need for a 30 amp circuit is to look at the AWG wire size chart here. You check the wire sizes with 30 or more ampacity ..., For a 400 amp service, the minimum wire size required is 3/0 AWG copper or 2/0 AWG aluminum. These wire sizes have an ampacity of 400 amps. Voltage drop is …, You'll need to consider wire strength and material when determining whether to use 2/0 AWG copper wire or 4/0 AWG aluminum or copper-clad wire. According to the NEC, these are the correct wire sizes for a 200-amp service: Service Rating (Amps) Copper (AWG) Aluminum or Copper-Clad (AWG) 100. 4. 2., InvestorPlace - Stock Market News, Stock Advice & Trading Tips Beyond Meat (NASDAQ:BYND)is at it again. As of this writing, Beyond Meat stock ... InvestorPlace - Stock Market N..., We used the formula: Power = Phase current × Phase voltage × Power factor. Try the Omnicalculator 100 amps wire size tool to get the proper wire you should install. Arturo Barrantes. The 100-ampere wire size calculator will assist you in choosing the proper wire size for your next equipment installation., A 100 amp service will need a minimum of 1.25 inches, schedule 40 or 80 PVC grey electric conduit. You can use a larger conduit to maintain the inner fill of 40% or less. A 1.5 or 2-inch conduit is best if running three or more electrical wires within the same electric conduit. Chapter 9, Table 5A of the 2020 NEC, #2 Aluminum-stranded insulated ..., Wire Size Calculator. Enter the information below to calculate the appropriate wire size. Voltage - Enter the voltage at the source of the circuit. Single-phase voltages are usually 115V or 120V, while three-phase voltages are typically 208V, 230V or 480V. Amperes - Enter the maximum current in amps that will flow through the circuit., If you are installing a 400 amp service then you can use conductors based on the table in art. 310 ... a calc I would use the 83% for the 200 amp service for the house and 200 amps for the shop which means you could use a wire rated for 366 amps . Reactions: augie47. electrofelon Senior Member. Location Cherry Valley NY, Seattle, …, Let’s examine what gauge wire is for 50 amp 220v circuits. According to the American Wire Gauge system, the correct 50 amp breaker wire size is 6 gauge. The 6 AWG copper wires are rated up to 55 amps, making it a good choice for this circuit. The American Wire Gauge system standardizes the ratings for conductors with a copper …, 400 amp service wire size chart • medinfo 2023 400 amp service wire size chart Copper 100 amp wire size chart: a comprehensive guide. Amps amperage awg sizes 12v conductor conductors magnetband dolap wirelessestimator. 400 amp service wire size chart400 amp service wire size chart 400 amp service wire size chart50 …, Southwire | Homepage, 5000. 700. 1200. 6000. 800. 1200. Note: View wire size charts from the list below. Maximum Allowable Ampacities for Conductors in Raceway, Cable or Earth (30°C) Maximum Allowable Ampacities for Conductors in Free Air (30°C) Maximum Allowable Ampacities for Conductors in Raceway, Cable or Earth (40°C) Maximum Allowable Ampacities for ..., 1385. 1560. 960. 1150. 1335. 2000. Note: View additional wire size charts from the list below. Maximum Allowable Ampacities for Conductors in Raceway, Cable or Earth (30°C) Maximum Allowable Ampacities for Conductors in Raceway, Cable or Earth (40°C) Maximum Allowable Ampacities for Conductors in Free Air (40°C) For ambient temperatures ..., 400 amp 3 phase service: For 400 amp 3 phase service, you will need a minimum of 600 kcmil-gauge wire. Before you upgrade to a 400 amp service, you will need permission from your electrical service provider. In some cases, you may also need to pay some upfront fee for the upgrade. However, in other cases it can be done for free., 400 Amp Service Wire Size Chart Inspire Your Ideas. Preview. 3 hours ago 400 amp service wire size chart. Only thing i can think of other than a mistake is it is a service with multiple service disconnects which would allow the wire to be sized to the load (in that case it shouldn't really be called an 800 amp service but if it was a panelboard with an 800 …, Table 310.15(B)(7) Allows me to use 400kcmil USE copper for a 400 amp underground residential service which in table 310.15(B)(16) would have an amperage rating of 335 amps. Now using the amperage rating of 2/0 USE, which is 175 amps, and running it in parallel would give a total ampacity of 350 amps., ALUMINUM SERVICE ENTRANCE CABLE, SIZE 2-2-2-4, 500 FT. per 1000 Each. 400 amp parallel service wire size Shop 8-8-8-8 aluminum ser service entrance cable (by-the-roll) at lowes.com Entrance service parts electric electrical cable install triplex wiring details installation diagram point residential lateral neutral power only basics code, Nanowires and Carbon Nanotubes - Nanowires are wires with a very small diameter, and can be used to build tiny transistors for processors. Learn about nanowires and how nanowires w..., A wire transfer is a method of transferring money electronically between two people or institutions. A wire transfer is a method of transferring money electronically between two pe..., The best wire size for 50 amp service is a 6 AWG wire. The wire size will change based on various factors, like wire material, voltage drop, and distance. So, the wire size is 6 AWG copper or 4 AWG aluminum. The longer the distance, the more the resistance and the voltage drop., Additionally, to have the proper size wire for 200 amps for that distance, you must raise the amps by 20%: 200 Amp Wire (100 ft away) = 250A × 1.2 = 300A Ampacity. It’d help if you used a 300A ampacity wire or higher. The 350 KCMIL wire is ideal for 100 feet distance, 200-amp service, as seen from the KCMIL list., The ground wire for 600-amp service: When it comes to the ground wire, we will need 1-kcmil gauge wire of copper wire and Aluminum 2/0-kcmil wires. Aluminum wire for 600-amp service: Now the size of aluminum wire for 600-amp service is 2000 kcmil. Copper wire for 600-amp service: In this case, we always need to follow a rule of thumb., When it comes to electrical installations and appliances, safety should always be the top priority. One critical aspect of ensuring safety is choosing the right wire size for the a..., Instead of throwing away or storing your old Linksys router, set it up as a switch, also known as a repeater. In doing so, you have the ability to hard-wire seven computers to your..., A wire transfer is a method of transferring money electronically between two people or institutions. A wire transfer is a method of transferring money electronically between two pe..., Wire Size Calculator. Enter the information below to calculate the appropriate wire size. Voltage - Enter the voltage at the source of the circuit. Single-phase voltages are usually 115V or 120V, while three-phase voltages are typically 208V, 230V or 480V. Amperes - Enter the maximum current in amps that will flow through the circuit., 400: 280: 335: 380: 225: 270: 305: 400: 500: 320: 380: 430: 260: 310: 350: 500: 600: 355: 420: 475: 285: 340: 385: 600: 700: 385: 460: 520: 310: 375: 420: 700: 750: 400: 475: 535: 320: 385: 435: 750: 800: 410: 490: 555: 330: 395: 450: 800: 900: 435: 520: 585: 355: 425: 480: 900: 1000: 455: 545: 615: 375: 445: 500: 1000: 1250: 495: 590: 665: 405 ..., Not sure how you all install 400 amp services. Around here we either use a 400 amp meter main- It has the meter and 2-200amp breakers in the panel that can be used to feed other panels. Some of these units also have extra circuits available in the panel area. The other method is to use a 400 amp meter with 2-200 amp panels with feed thru lugs., According to the National Electrical Code (NEC), for a 50 amp circuit with a length of 200 feet, you’d typically need a 4-gauge or 2-gauge wire. But hold your horses! This is just a general guideline. Other factors, like voltage drop, may affect the exact size needed.